Panasonic AW- PH350 Digital Camera User Manual


 
O I
CONTROL OUT TO
PAN/TILT HEAD
VIDEO/Y IN
G/L OUT
VIDEO IN
VIDEO/Y OUT
Y/VIDEO OUT
G/L IN
CONTRTOL IN IP/RP
REMOTE
Examples of connections
1. When controlling the camera and pan-tilt head using the AW-RP605 multi-function
controller and transmitting composite signals
Color monitor
Pan-tilt head cable:
AW-CA50T29
Printed circuit board
switches:
Analog settings
Multi-Function Controller:
AW-RP605
Genlock signals must be supplied when
more than one camera and pan-tilt head
are to be used.
AC adapter:
AW-PS300
Coaxial cables:
BELDEN 8281, max. 3,280 feet
(1,000 meters)
Cable with a nominal cross
section of 1.25 mm
2
or more
max. 98.4 feet (30 meters)
Coaxial cable:
BELDEN 8281
10BASET straight cable:
UTP category 5,
max. 3,280 feet (1,000 meters)
OUse the camera/pan-tilt head connecting cable (AW-CA50T29) to connect the pan-tilt
head with the convertible camera.
OSet the printed circuit board switches to the analog settings.
OUse a coaxial cable (BELDEN 8281) to connect the Y/VIDEO OUT connector on the
pan-tilt head with the VIDEO/Y IN connector on the controller.
OUse a 10BaseT straight cable (UTP category 5) to connect the CONTROL IN IP/RP
connector on the pan-tilt head with the CONTROL OUT TO PAN/TILT HEAD
connector on the controller.
OUse a coaxial cable (BELDEN 8281) to connect the VIDEO/Y OUT connector on the
controller with the VIDEO input connector on the color monitor.
OCheck that the pan-tilt head and camera can be controlled using the controller.
Personal computer
(Windows)
23