SERIAL COMMAND SET
Serial Command Set Usage
28 SuperView 3000 User Manual May 9, 2002
6
INPUT COMMANDS
These commands allow you to make adjustments for your inputs and then save
these settings into the unit’s internal memory.
Command Arguments Description
INput <input # | ALL> [AUTO |
LOCK | DEBUG]
Sets the input mode for the specified input. Auto engages
the autosync circuitry. Lock turns the autosync circuitry
off. Debug provides information on input status and
reports changes to measured parameters.
Factory default: AUTO
INputDELete <1…50> Deletes the specified saved input from the Input List.
INputFormat <input #> InputFormat is a read-only command for checking the
video format of the current video input selection. The
command is only valid when Input Type is set to either
Composite, Component, or S-Video. The response to the
command will be NTSC or PAL.
INputInteractive <input#> Enters input interactive mode to visually adjust timing
parameters of the specified input. A white box frame and
cross hair appear over the full screen input.
Starting with the upper-left corner of the image, use these
keyboard controls to position the image within the white
frame:
i = move up m = move down
j = move left l = move right
With the upper-left corner properly adjusted, address the
lower-right corner next by using these keyboard controls:
I =moveup M = move down
J = move left L = move right
With the image properly adjusted, quit the utility:
q = quit
After you have adjusted the input to your satisfaction, use
the Input Name command to name your input source, and
the Input Save command to store the setting to the Input
List.
INputLIST [<1…50>] [<1…50>]
[<ACTIVE>]
Displays the entire Input List of saved input timings. If
arguments are supplied, displays only the portion of the list
requested. The Active argument displays all saved list
entries.
INputLOAD <input #> <1…50> Loads the indicated entry from the Input List to the
specified input channel. The entry is loaded only if it
matches the measured parameters of the signal—sync
format and polarity, interlace state, vertical total, and
horizontal frequency.
INputName <input #> <name> Assigns a name to the specified input. The argument can
be up to 17 alphanumeric characters with no spaces
(underscore is acceptable).
Factory default: Auto_1
INputSave <input#> <1…50> Saves the specified input to the selected entry in the Input
List. These settings are recalled whenever the signal is
reappliedtotheSuperView.
INputTiming <input #> <hfp> <hs> <hbp>
<hact> <vfp> <vs> <vbp>
<vact>
Sets the timing of the selected input.
Note: The vertical total cannot be changed from the
measured value; that is, the total of <vfp> + <vs> + <vbp>
+ <vact> must remain constant.
See Table 4 for acceptable ranges.