RGB Spectrum SuperView 3000 Camcorder User Manual


 
SERIAL CONTROL OF MULTIPLE UNITS
MPSD Example: Baud Rate Change
58 SuperView 3000 User Manual May 9, 2002
D
can enter MPSD commands. Selecting the next upstream device in the chain,
which is still at the old baud rate, re-establishes communication.
After changing the baud rate for the console, the :unassign command is
issued to clear out the serial buffer before re-establishing communication once
again with Device 0.