1-2. VBS phase adjustment
1 Connect a VBS signal source to the VBS IN connector on the
camera.
The on-screen setting will automatically switch to VBS. Press the
CURSOR (j or l) button to select the on-screen VBS setting
(get it flashing), then press the SET button. The adjustment
sub-menu “ADJUSTMENT FOR VBS” will be displayed.
2 Press the CURSOR (d or c) button to adjust the horizontal phase
(H). The on-screen marker (b) will move and the adjustment value
will flash according to the horizontal phase setting.
When finished setting the horizontal phase (H), press the
CURSOR (l) button to select the sub-carrier (SC) phase.
3 Press the CURSOR (d or c) button to adjust the sub-carrier (SC)
phase. The on-screen marker (b) will move and the adjustment
value will flash according to the sub-carrier phase setting.
Note:
When an adjustment is made, the PRESET setting will
automatically switch to OFF. To return to the initial values, just
return the PRESET setting to ON, then press the SET button.
4 When finished.
(Refer to step 3 on page 15.)
Note:
If using a VS sync signal, the H sync phase adjustment is made by
following the same method as described for the “VBS phase
adjustment”.
MENU FOR ADJUSTMENT
SYNC VBS
IRIS AI
BLC ON
SET
CURSOR
ADJUSTMENT FOR VBS
(PHASE)
H o------z------p 280
SC o------z------p 90
L53P4/US GB 1998, 3, 11