Sony HSR-X200P Security Camera User Manual


 
25 (GB)
3 Turn the Jog dial to highlight the item to be set and
turn the Shuttle dial clockwise to finalize your
selection.
The current setting on the selected line flashes.
4 Turn the Jog dial to change to the desired setting
and turn the Shuttle dial clockwise to register the
new setting.
When you set REC CYCLE for ALARM
RECORDING, the number of alarm events that
can be recorded is automatically calculated
according to the PICTURE QUALITY setting and
the available alarm recording area size and
displayed in parentheses on the third line from the
bottom.
Note
As long as the normal recording area has been
established on the hard disk, the recording cycle
for pre-alarm recording is limited to 0.05 SEC
(HSR-X200) or 0.06 SEC (HSR-X200P) at
maximum. If you cancel the normal recording area
(by setting the area to 0%), the recording cycle for
pre-alarm recording can be set to 0.02 SEC at
maximum.
5 When you use the built-in activity detection sensor
as a trigger, set the sensing points and the
sensitivity (see below).
6 When the settings on the ALARM REC MODE
SET display are completed, press the EXIT/OSD
button to exit the menu
Setting the activity detection sensor
When you use the built-in activity detection sensor, it
is necessary to set the sensing points and the
sensitivity.
Highlight ACTIVITY SENSOR and turn the Shuttle
dial clockwise to enter Sensor Set mode.
The sensor marks are displayed on a 10 × 8 grid on the
monitor, and the top left mark flashes.
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
LEVEL : 1 EXIT
To turn on the sensor at a point
Turn the Jog dial so that the mark at the point where
you wish to activate the sensor flashes, and turn the
Shuttle dial clockwise so that the flashing mark
changes to
x
.
Set the marks at all the points where you wish to
activate the sensor to
x
in the same manner.
Example:
- - - - - - - - - -
- - - - - - - - - -
- - -
x
x
x
- - - -
- - -
x
x
x
- - - -
- - -
x
x
x
- - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
LEVEL : 1 EXIT
To set the sensitivity
You can select the sensitivity level in the range of 1 to
10. The smaller the value you select, the higher the
sensitivity becomes. Setting to 1 provides the highest
sensitivity.
1 Turn the Jog dial clockwise at the bottom right
sensor point to highlight LEVEL and turn the
Shuttle dial clockwise.
The current setting flashes.
The sensor is deactivated with LEVEL set to OFF.
2 Turn the Jog dial to display the desired value, and
turn the Shuttle dial clockwise to register the
setting.
To end sensor setting
Highlight EXIT and turn the Shuttle dial clockwise.
The previous display will be restored.