Sony HSR-X200P Security Camera User Manual


 
58 (GB)
Maintenance
Troubleshooting
This section may help you isolate a problem. Should
the problem persist, unplug the unit and contact your
Sony dealer or local authorized Sony service facility.
If a system shutdown occurs
If the recorder does not operate at all, do the following:
1 Make sure the recorder is connected to the power
supply.
2 Turn the power off by disconnecting the power
cord.
3 Reconnect the power cord to turn the power on.
4 Press the All Reset button on the rear panel.
If the recorder still does not operate, please consult the
dealer from which you purchased the recorder.
Symptom Possible cause Corrective action
The picture does not appear on Wrong connection Check the connection.
the monitor screen.
No power is provided to the video camera Turn on the power.
and/or monitor.
The recorder does not respond The recorder is in alarm recording. Wait for the alarm recording to finish.
when you press any button.
The security lock function is working. Release the security lock.
See page 49(GB).
The recorder is in timer-recording Press the TIMER button so that the indicator
standby status or during timer recording. goes dark.
See page 28(GB).
Timer recording was not made. The clock setting is not correct. Set the clock to the correct time.
See page 44(GB).
Timer recording is not set to on. Press the TIMER button so that the indicator
lights.
See page 28(GB).
Check the TIMER SET display to see
whether ON is displayed in the SET column.
See page 27(GB).
The time and date were not The on-screen data is made undisplayed. Press the EXIT/OSD button.
recorded.
See page 16(GB).
The TIME/DATE displays are set to OFF. Set them to ON with DISPLAY SET.
See page 48(GB).
A warning message appears that There is a problem with your unit. Please contact your Sony dealer.
cannot be cleared from the screen.