Sony SNC-DF70N Security Camera User Manual


 
Administrating the Camera
Downloading Images from the Camera — FTP server setting Menu / Setting the Alarm Output — Alarm output setting Menu
47
Downloading Images
from the Camera
— FTP
server setting Menu
When you click FTP server on the Administrator menu,
the FTP server setting menu appears. Use this menu to
set up for the FTP server function which finds a
specified image and audio file stored in the built-in
memory of the camera (about 8 MB) or download the
still image file from the camera.
FTP server function
To activate the FTP server function, select On and click
OK.
When you do not use the FTP server function, select Off
and click OK.
OK/Cancel
See “Buttons common to every setting menu” on page
24.
Note
Note the followings when you log in the FTP server of
the camera using the FTP client software of the
computer.
The frame rate and the operativity of the monitor
window in the main viewer will degrade.
While recording the image using the Image memory
function, you cannot delete the recording directory.
When the recorded image or audio file is deleted, the
camera counts the free space of the built-in memory
again at logging off.
Setting the Alarm Output
— Alarm output setting Menu
When you click Alarm output on the Administrator
menu, the Alarm output setting menu appears.
You can set in this menu to control the alarm out of I/O
port on the rear of the camera linked to the alarm
detection, the timer and day/night.
Alarm out 1, 2 Tab
Alarm output
To activate the Alarm output function, select On. The
basic setting options are displayed below.
When you do not use the Alarm output function, select
Off.
Mode
Select the mode of the Alarm output function.
Alarm: Controls alarm output by synchronizing with an
external sensor input or the built-in activity detection
function.
Timer: Controls alarm output by the timer.
Day/Night: Controls the alarm output linked to the day/
night function.
Alarm
This item is displayed when Mode is set to Alarm.
Select the alarm to link the alarm output function. If the
selected alarm is detected, the alarm output status
changes.
Sensor input: External sensor connected to sensor input
of the camera I/O port
Motion detection: To set the motion detection function,
click Motion detection. The Motion detection
setting menu appears (see page 52).