14 RT-PRC005-EN
General
Data
(3 - 5 Ton)
Standard Efficiency
Table GD - 1 — General Data
3 Ton Convertible Units 4 Ton Convertible Units 5 Ton Convertible Units
TSC036A1, A3, A4, AW TSC048A1 TSC048A3, A4, AW TSC060A1 TSC060A3, A4, AW TSC060AK
Cooling Performance
1
Gross Cooling Capacity 37,400 50,300 49,200 63,100 63,100 63,100
SEER
2
10.7
5
10.1 10.0 9.9 10.2 10.2
Nominal CFM / ARI Rated CFM 1,200/1,200 1,600/1,600 1,600/1,600 2,000/2,000 2,000/2,000 2,000/2,000
ARI Net Cooling Capacity 36,000 48,000 47,000 60,000 60,000 60,000
System Power (kW) 3.79
8
5.28 5.40 6.86 6.78 6.78
Compressor
No./Type 1/Recip. 1/Scroll 1/Scroll 1/Scroll 1/Scroll 1/Scroll
Outdoor Sound Rating (dB)
3
83 86 82 84 84 84
Outdoor Coil — Type Lanced Lanced Lanced Lanced Lanced Lanced
Tube Size (in.) O.D. 0.3125 0.3125 0.3125 0.3125 0.3125 0.3125
Face Area (sq ft) 7.19 6.17 9.59 8.81 8.81 8.81
Rows/FPI 2/17 2/17 1/17 2/17 2/17 2/17
Indoor Coil — Type Lanced Lanced Lanced Lanced Lanced Lanced
Tube Size (in.) 0.3125 0.3125 0.3125 0.3125 0.3125 0.3125
Face Area (sq ft) 5.67 6.68 6.17 5.00 5.00 5.00
Rows/FPI 2/16 3/16 3/16 3/16 3/16 3/16
Refrigerant Control Short Orifice Short Orifice Short Orifice Short Orifice Short Orifice Short Orifice
Drain Connection No./Size (in.) 1/¾ NPT 1/¾ NPT 1/¾ NPT 1/¾ NPT 1/¾ NPT 1/¾ NPT
Outdoor Fan — Type Propeller Propeller Propeller Propeller Propeller Propeller
No. Used/Diameter (in.) 1/22 1/22 1/22 1/22 1/22 1/22
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 Direct/1 Direct/1
CFM 2550 2850 3610 3470 3470 3470
No. Motors/HP 1/.20 1/.33 1/.33 1/.33 1/.33 1/.40
Motor RPM 1115 1115 1115 1115 1115 1115
Direct Drive Indoor Fan — Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used 1 1 1 1 1 1
Diameter x Width (in.) 10 x 10 11 x 11 11 x 11 11 x 11 11 x 11 12x11/–
Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 Direct/2 Direct/2
No. Motors 1 1 1 1 1 1
Motor HP (Standard/Oversized) .33/.50 .60/.80 .60/.80 .90/1.00 .90/1.00 1.0/–
Motor RPM (Low/High Speed) 950/1060 930/1000 930/1000 985/1100 985/1100 935/1100
Oversized Motor RPM
(Low/High Speed) 1100/1145 1000/1100 1000/1100 1080/1135 1080/1135
Motor Frame Size
(Standard/Oversized) 48/48 48/48 48/48 48/48 48/48 48/—
Belt Drive Indoor Fan — Type FC Centrifugal FC Centrifugal FC Centrifugal
No. Used 1 1 1
Diameter x Width (in.) 11 x 11 11 x 11 11 x 11
Drive Type/No. Speeds Belt/Variable Speed
6
Belt/Variable Speed Belt/Variable Speed
No. Motors 1 1 1
Motor HP 1.00 1.00 1.00
Motor RPM 1750 1750 1750
Motor Frame Size 56 56 56
Filters — Type Furnished
7
Throwaway Throwaway Throwaway Throwaway Throwaway Throwaway
(No.) Size Recommended (in.) (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1 (2) 20 x 25 x 1
Refrigerant Charge (Lbs of R-22)
4
3.8 4.4 3.8 4.7 4.9 4.9
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes
the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is
based on ARI Standard 210/240 except AK (380V/60 Hz).
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-72.
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
5. TSC036A1 SEER is 10.5.
6. Belt Drive Motor is not available for TSC036A1.
7. Optional 2” Pleated Filters also available.
8. TSC036A1 System Power (kW) is 3.91.