VBrick Systems VB6000 Security Camera User Manual


 
VBStar
VBrick MPEG-2 Appliance Admin Guide 101
Configuration: Pump > General
Click here to examine ... Click on this link to examine hard drive content. You must know
the user name and password to login to the FTP server and view
content. You can use any FTP client application to access the
hard drive using a URL like this:
ftp://admin@<IP_Address>/D:
Be sure to login to the D: drive as shown. Do not modify or
store files on the C: drive. The C: drive has limited space and is
reserved for VBrick firmware.
Pump Mode Used to set the stream to be controlled manually or to
automatically start at the VBStar Power-Up.
Pump File Name This is the file that will "Pump". In batch mode, the Batch Base
File Name is usually entered as the Pump File Name, the batch
files will be played from the lowest numbered through the
highest number. If a batch file name is entered with a particular
batch file number, the file will be pumped using that file as the
starting point. Any missing files in the series will be skipped and
the next sequential file will play.
Example: If files test1.mpg through test15.mpg exist and the
user specifies test5.mpg, test5.mpg through test15.mpg will be
played. After playing test15.mpg, test5.mpg will be played again,
even though lower numbers of the file exist.
IR Enable Is used to enable or disable the use of IR Controller to "Pump"
the specified stream.
Batch Enable If enabled, a series of files in a batch will be played sequentially.
If disabled, only a single file will be played.