VBrick Systems VB6000 Security Camera User Manual


 
Status
VBrick MPEG-2 Appliance Admin Guide 63
Status: Network Status
Status: Network Status > Codec
This menu allows the user to view various network-level conditions.
DHCP Status Dynamic Host Configuration Protocol – Ethernet models only.
Enabled/Disabled. Possible DHCP Status values:
•Disabled
Succeeded
•Failed
Succeeded without Subnet Value – No subnet value given;
generated from IP address.
Succeeded with Invalid Subnet Value – Invalid subnet value given;
generated from IP address.
Failed over Backplane – Device number invalid in backplane.
Failed, Invalid Device Unit – Network interface device number
invalid.
Failed Invalid Cookie – Network interface inoperable.
Failed, Bind Failed – DHCP server not available or appliance not
connected to network.
Failed, Out of Memory – Appliance is out of memory. Indicates a
severe condition.
Failed, Parameter Get Failed – Couldn't retrieve a DHCP
parameter needed/requested.
Failed, Invalid Boot File – Invalid boot file specified. Indicates a
severe condition.
Failed, Invalid Retrieved IP address assigned by the server is not a
valid unicast address.
Temperature Displays the temperature of the appliance (Celsius).
Fan State Displays the state of the fan as
Not Operational, High or Low.
Battery Status OK or Failed.
Overloaded Count Provides a count of the number of times the box has entered the
Overloaded state.
CPLD version Displays the Main Board programmable device version number.
Boot Revision Displays the date of the last boot revision.
Code Revision Displays the date of the last code revision.
Release Revision Displays the release version number.
CPU Utilization% The percentage of the Central Processor in use at this time.
Power Supply
Voltage
Displays the measured voltages present and provided to the VBrick
(24V, 12V, 5V, 3.3V 2.5V). The tolerance range for 24V is minimum
18V to maximum 25V. The range for all other voltages is plus or
minus 5%.