American Dynamics RAS917WLS-1 Security Camera User Manual


 
Additional AD-UTC Commands
The following tables summarize the special commands available when using the dome in an AD-UTC
network. These commands are available when you enter the keyboard combination provided.
If you want to … Use …
Program selected Preset
F
, Preset number,
(Function, Preset number (1-
96), and then Preset)
Recall selected Preset
Preset number,
(Preset number, then Preset)
Start selected Pattern programming
F
, pattern number, +
(Function, pattern number (1-3),
then Shift+Preset)
Save Pattern programming
Pattern number,
F
(Pattern number (1-3), then
Function)
Run selected Pattern continuously
Pattern number, then
and
(Pattern number, Shift and
Preset)
Resume Auto Focus mode
F
+
or
F
+
(Function+Focus Far or
Function+Focus Near)
Resume Auto Iris mode
F
+
or
F
+
(Function+Iris Open or
Function+Iris Close)
Rotate dome 180° from current position (“flip”)
(Flip)
AD Up-the-Coax (UTC) Command Summary E–3