American Dynamics RAS917WLS-1 Security Camera User Manual


 
AD168
Supported Protocols SensorNet
(1)
RS-422
(1) or (2)
Maximum Presets 16
(1)(2)
, 64
(1)(3)
, or 60
(4)
Maximum Patterns
(5)
3
Quick Set Menu Not supported
Address Range SensorNet: 1-180
RS-422: 1-99
(1)(6)
or
1-180
(2)(6)
Notes:
(1) Requires the appropriate code control module.
(2) Requires the AD2083-02 series code converter.
(3) Presets information is stored at the converter or control
module, not the dome.
(4) Requires AD2083-02 with firmware version 0701-11YB-
156A or newer. Preset information is stored in the
dome, not the converter.
(5) Patterns are limited by time and the number of available
dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.
(6) Requires additional equipment to achieve these
numbers. A dome address within each group of 64 or 99
cameras is reserved as a global broadcast address.
AD2050
Supported Protocol RS-422
(1)
Maximum Presets 16
(2)
or
60
(3)
Maximum Patterns
(4)
3
Quick Set Menu Not supported
Address Range 1-1024
(5)
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-11YB-
156A or newer. Preset information is stored in the
dome, not the converter.
(4) Patterns are limited by time and the number of available
dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.
(5) Requires additional equipment to achieve these
numbers. A dome address within each group of 64 or 99
cameras is reserved as a global broadcast address.
MegaPower LT
Supported Protocol SensorNet
Maximum Presets 96
Maximum Patterns
(1)
3
Quick Set Menu Yes
(2)
Address Range 1-32
Notes:
(1) Patterns are limited by time and the number of available
dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.
(2) Requires a compatible keyboard.
MegaPower 48
Supported Protocols SensorNet
RS-422
Maximum Presets 96
(1)
Maximum Patterns
(2)
3
Quick Set Menu Yes
(3)
Address Range 1-48
Notes:
(1) Preset information is stored at the host, not the dome.
(2) Patterns are limited by time and the number of available
dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.
(3) Requires firmware 1.07 or newer and a compatible
keyboard.
MegaPower 1024
Supported Protocol RS-422
(1)
Maximum Presets 16
(2)
or
60
(3)
Maximum Patterns
(4)
3
Quick Set Menu Not supported
Address Range 1-1024
(5)
Notes:
(1) Requires the AD2083-02 series code converter.
(2) Preset information is stored at the converter, not the
dome.
(3) Requires AD2083-02 with firmware version 0701-11YB-
156A or newer. Preset information is stored in the
dome, not the converter.
(4) Patterns are limited by time and the number of available
dome commands. Total time for each pattern cannot
exceed 6 minutes 50 seconds. Total dome commands
used in all patterns cannot exceed 99.
(5) Requires additional equipment to achieve these
numbers. A dome address within each group of 64 or 99
cameras is reserved as a global broadcast address.
SensorNet and RS-422 Command Summary A-5