1.3 Important notices
All-pole power switch - Incorporate an all-pole power switch,
with a contact separation of at least 3 mm in each pole, into the
electrical installation of the building. If it is needed to open the
housing for servicing and/or other activities, use this all-pole
switch as the main disconnect device for switching off the
voltage to the unit.
Camera signal - Protect the cable with a primary protector if
the camera signal is beyond 140 feet, in accordance with
NEC800 (CEC Section 60).
This product has been tested according to standard CIE/IEC
62471:2006 “Photobiological safety of lamps and lamp
systems” and found to meet Risk Group 1 for exposure limit
4.3.7 “Infrared radiation hazard exposure limits for the eye.”
For other hazard exposure limits, the product was found to be
exempt. Risk Group 1 is characterized in the standard as
“products are safe for most use applications, except for very
prolonged exposures where direct ocular exposures may be
expected.” Risk Group 1 sources do not pose an infrared
radiation hazard for the eye for times less than 100 s at
distances beyond 200 mm or 8 inches.
Accessories - Do not place this unit on an unstable stand,
tripod, bracket, or mount. The unit may fall and cause serious
injury and/or serious damage to the unit. Use only with the
cart, stand, tripod, bracket, or table specified by the
manufacturer. When a cart is used, use caution and care when
moving the cart/apparatus combination to avoid injury from
tip-over. Quick stops, excessive force, or uneven surfaces may
cause the cart/unit combination to overturn. Mount the unit
per the manufacturer's instructions.
NOTICE!
RISK GROUP 1
IR emitted from this product.