| 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
3. Navigate to the Livepage for the camera (refer to
Section 6 Operation via the browser, page 42) and observe
the Input 1 symbol.
4. Slowly turn the potentiometer counter-clockwise until the
Input 1 symbol lights up. The camera is now in Mode 2
(FullSun) and the image appears dimmed slightly.
5. If the image is still too bright, navigate to the Settings page
for the camera.
From the Livepage, click the Settings link at the top of
the page.
Click the Advanced Mode link, then navigate to
Camera>Picture Settings>Shutter/AGC.
Lower the Fixed gain setting until the desired image is
achieved.
If the lowest gain setting is reached and the image is
still too bright try changing the shutter to 1/10000.
To disable Automatic Mode Switching:
1. Navigate to the Settings page for the camera, under the
Advanced Mode link, click the Interfaces link, then click
Alarm Inputs.
2. Select None for the Action option. Refer to
Section 8.7.1 Alarm input, page 103, for more information.
NOTICE!
Shutter can also be changed to adjust plate brightness. Shutter
is fixed at 1/5000 from the factory and should be changed only
by an experienced user. Changing the shutter speed affects
maximum capture speed of the vehicle and ambient rejection
ability.