Bosch Appliances 550 Security Camera User Manual


 
MIC Series 550 Camera Getting Started | en 23
Bosch Security Systems, Inc. User Manual F.01U.239.454 | 3.0 | 2012.09
6 Getting Started
Install and wire the camera according to the instructions in this manual and in the manuals
that accompany the power supply and mounting devices. A typical system includes a
keyboard, matrix switcher, monitor, and appropriate wiring connections. Refer to the
individual product manuals for complete installation and setup instructions for each of the
system components.
6.1 Establishing Control of the Camera
The MIC-550 supports two communication protocols (Biphase and RS-485), and both Bosch
and Pelco D and P (keyboard) controller protocols that allow you to send commands to the
camera and to receive information from the camera.
6.1.1 Establishing Control of the Camera via Biphase Protocol
Shielded 2-wire, half-duplex, multi-drop, 5000 ft. cable limit
Biphase is the standard Bosch protocol used to send Pan/Tilt/Zoom control over 2-wire
shielded twisted pair (STP) terminated with a 100 Ω terminal resistor. Biphase connections
require a MIC-BP3 or a MIC-BP4 Biphase converter (sold separately).
6.1.2 Establishing Control of the Camera via RS-485 Protocol
2-wire (shielded), half-duplex, differential, multi-drop (32 nodes), 4000 ft cable limit
RS-485 is capable of controlling a true multi-drop network and is specified for up to 32 drivers
and 32 receivers on a single 2-wire bus. The MIC-550 camera uses the 2-wire mode, although
RS-485 can be connected in a 2- or 4-wire mode.
NOTICE!
Biphase protocol works only with Bosch controller protocol. It does not work with Pelco
controller protocol.
CAUTION!
The Biphase shield must be connected to the head end only.
Cable Type STP - Shielded Twisted Pair
Distance 1524 m (5000 ft) Belden 8760 recommended
Transmission Rate 31.25 KHz
Gage 1.02 mm (18 AWG)
Termination 100 Ω
Terminal Connector Screw terminals
Voltage 4 Vp-p
NOTICE!
In Pelco controller protocol, RS-485 is the only communication protocol that the MIC-550
supports. It does not transmit responses back to the controller.
NOTICE!
The wire shield must be tied to signal at both ends, if 2-wire twisted pair is used. After
connecting the wires for RS-485 operation, ensure that the slide switch on the main board to
the camera head is positioned toward the LEDs (default).