Pelco-P protocol must use addresses 1 to 32.
Pelco-D protocol must use addresses 1 to 254.
To set FastAddress with a Pelco Keyboard:
1. Press and hold 95-PRESET for two seconds to open the Pelco Setup menu.
2. Move the joystick to select the Command Lock menu.
3. Press the FOCUS or the IRIS button to turn Command Lock to OFF.
4. Move to the FastAddress menu and press the FOCUS or the IRIS button to open the
menu.
5. Use the joystick to enter the unique identifier for the MIC-550.
Move the joystick up or down to select the number.
Move the joystick right to move to the next number position.
6. Move the joystick right to select Continue. Then, press the FOCUS or the IRIS button.
7. Use the keyboard to enter the FastAddress number. Then, press the Camera button.
Note: You must first clear an assigned FastAddress number to use the number for a
different MIC-550.
8. Move the joystick down then back up to set the FastAddress number.
9. Press the FOCUS or the IRIS button to store the FastAddress number.
The on-screen display menu confirms that the MIC-550 stored the FastAddress number.
6.5 Setting Passwords
Passwords are used to control access to locked command menus. Unlocked commands are
available to all users. Passwords are four (4) digits in length.
6.5.1 Special Passwords
The table below identifies special passwords and their function and security level.
6.5.2 Setting Passwords, Bosch Protocol
To set or change a password (locked command):
1. Press OFF-90-ENTER to turn off the command lock.
2. Press SET-802-ENTER to access the password menu.
3. Tilt the joystick up or down to choose a number. Tilt the joystick right to move to the next
number position.
4. Follow the on-screen instructions and save the password. You receive an on-screen
confirmation. If you do not change the password, when you exit, the OSD displays the
message, "Password Not Changed!"
NOTICE!
A previously-configured MIC-550 with an address above 32 (Pelco-P upper limit) or 254
(Pelco-D upper limit) can be used without readdressing the unit. However, no two (2)
addresses can be the same. For example:
Pelco-P addresses above 32 are repeated in multiples of 32 (1, 33, 65, 97 are the same).
Pelco-D addresses above 254 are repeated in multiples of 254 (1, 255, 509, 763 are the
same).
Password Function / Security Level
0000 (default) Enables security and requires a user to enter the unlock command
OFF-90-ENTER before invoking a locked command.
9999 Disables all security and allows all users to access locked commands.