Bosch Appliances 550 Security Camera User Manual


 
MIC Series 550 Camera | en 61
Bosch Security Systems, Inc. User Manual F.01U.239.454 | 3.0 | 2012.09
A.2 Keyboard Commands By Number (Pelco Protocol)
On/Off 101 Record B Activate/Deactivate
102 Wiper alarm Manual on/off
103 Wiper wipe Intermittent; wipes twice, then turns off after 15
seconds.
104 Wiper wipe On shot; wipes five times, then turns off.
105 Washer/Wiper Activate
On 997 FastAddress, display Display current address
On 998 FastAddress, all units Display and program current address
On 999 FastAddress, unaddressed cameras Display and program unaddressed MIC-550 units
Set “1-99” Pre-position Programming Set ##–Programs a preset view
Shot “1-99” Pre-position Recall Shot ##–Recall programmed preset
Set 100 Pre-position Menu Enters the Pre-position menu
Set/Shot 101 Autopan Left Limit Set–Programs left limit
Shot–Shows limit
Set/Shot 102 Autopan Right Limit Set–Programs right limit
Shot–Shows limit
Set 110 Factory P/T Home Position Set–Recalibrate home position
* Set 802 Edit Password Enters the Edit Password menu
* Set 899 Reset ALL Restores all settings to original defaults and
clears all user-programmed settings
Set 900 Edit Tour 1 (Standard) Enters the Standard Tour Scene menu
Shot 900 Edit Tour 2 (Custom) Enters the Custom Tour Scene menu
Set/Shot 901-999 Adds/Removes a Preposition Shot
from Tour 1
Set ###–Adds preset
Shot ###–Removes preset
Locked Function
Key
Command
No.
Command Description
Keyboard
Command
User Action Description
33 - Preset PressPress Pans the AutoDome 180° (Flip)
34- Preset Press Goes to Zero Pan (original home position)
80 - Preset Press Toggles Synch. Mode between Line Lock and Internal.
No dependency on power on time.
81 - Preset Press Initiates the AutoDome standard preset tour (Tour 1)
82 - Preset Press Initiates the AutoDome custom preset tour (Tour 2)
92 - Preset Press and hold
(2 seconds)
Sets the Left pan limit for an AutoScan with Limit
Stops enabled
93 - Preset Press and hold
(2 seconds)
Sets the Right pan limit for an AutoScan with Limit
Stops enabled
95 - Preset
Press Enables or disables Limit Stops in the Setup Menu for
AutoScan.
Press and hold
(2 seconds)
Invokes the Pelco main Setup Menu when pressed for 2
seconds.
96 - Preset Press Stops a scan
97 - Preset Press Initiates FastAddress process (Pelco Random Scan)
98 - Preset
Press Toggles the Synch. Mode between Line Lock and
Internal (Pelco Frame Scan). Available only within 2
minutes after power is applied.
Press and hold
(2 seconds)
After 2 minutes of applied power, command reverts to
normal preset functionality.
99 - Preset Press Initiates an AutoScan