Bosch Appliances 550 Security Camera User Manual


 
40 en | On-Screen Display (OSD) Menus (Bosch Protocol) MIC Series 550 Camera
F.01U.239.454 | 3.0 | 2012.09 User Manual Bosch Security Systems, Inc.
Rule Setup Submenu
Rule Setup Submenu Choices:
Outputs 1-4 Defines a physical output. N.O.: Normally open circuit
N.C.: Normally closed circuit
N.O.
Outputs 5-12 Defines a command output
for use in a rule.
Aux On: A keyboard ON command.
Aux Off: A keyboard OFF command.
Shot: Recalls a preset shot.
OSD: Displays the output on the on-
screen display.
Transmit: Transmits a message back
to the head end (available with RS-232
serial and Bilinx connections).
NONE: No command defined.
NONE
Outputs 5
and 6 set
to OSD
and Shot 1
Menu Description Submenu / Description Default
Setting
NOTICE!
You can program a total of twelve rules. You must define the inputs and outputs before you
program a rule. See Section 7.6 Alarm Setup, page 38, to configure alarm inputs and outputs.
Rule Setup... Rule 1
Exit... Exit...
1. Rule 1 Enabled Enabled YES
2. Rule 2 Disabled Input:
3. Rule 3 Invalid NONE
4. Rule 4 Empty NONE
5. Rule 5 Empty NONE
6. Rule 6 Empty
7. Rule 7 Empty Output:
8. Rule 8 Empty OSD
9. Rule 9 Empty Shot 2
10. Rule 10 Empty Alarm Relay 2 sec
11. Rule 11 Empty NONE
12. Rule 12 Empty
Right / Left: Select Period Time
Focus / Iris: Select Focus / Iris: Select Type
Menu Description Submenu / Description Default
Setting
Exit Saves and exits the menu.