Bosch Appliances 550 Security Camera User Manual


 
MIC Series 550 Camera On-Screen Display (OSD) Menus (Bosch Protocol) | en 43
Bosch Security Systems, Inc. User Manual F.01U.239.454 | 3.0 | 2012.09
Diagnostic Events
Alarm Status Submenu
This menu displays the status of the alarm inputs and outputs.
Menu Description Submenu / Description
Exit Saves and exits the menu.
Alarm Status Enters the Alarm Status menu and displays
the real time status of alarm inputs and
outputs.
Alarm Inputs 1 to 8,
Alarm Outputs 1 to 2
(Closed or Open)
BIST Enters the Perform Built-in Self Tests menu.
If confirmed, the BIST tests start and the
results are displayed.
YES to start test.
NO to exit the menu.
Typical results are:
BIST
Exit...
Data Flash: PASS
FPGA: PASS
Bilinx: PASS
Internal Temp. Displays the current temperature of the
camera, in degrees Fahrenheit and in degrees
Celsius.
High Temp Events Displays the number of times that the
threshold of high temperature was exceeded.
Highest Temp Displays the highest temperature reached, in
degrees Fahrenheit and in degrees Celsius.
Low Temp Events Displays the number of times that the
threshold of low temperature was exceeded.
Lowest Temp Displays the lowest temperature reached, in
degrees Fahrenheit and in degrees Celsius.
Internal Humidity Displays the percentage of humidity inside
the camera housing.
Humidity Events Displays the number of times that the
threshold of the humidity inside the camera
housing was exceeded.
Security Access Displays the number of times that the locked-
command menu is unlocked.
CTFID Access Displays the number of times that the
Configuration Tool is accessed.
Restart Events Displays the number of restart events.
Low Volt Events Displays the number of times that the camera
dropped below the acceptable voltage limit.
Power Up Events Displays the number of power up events.
Video Loss Events Displays the number of time that video was
lost.
Total Time On Displays the total time that the video has
been on.
Alarm Status
Exit...
Alarm Input 1 Open
Alarm Input 2 Open
Alarm Input 3 Open
Alarm Input 4 Open