Bosch Appliances VG5 800 SERIES Security Camera User Manual


 
106 en | Configuring the AutoDome 800 Series AutoDome 800 Series HD PTZ Camera
F.01U.273.797 | 5.0 | 2012.08 Installation Manual Bosch Security Systems, Inc.
7.49.2 IPv6
Consult with the network administrator before making changes to the this section.
IP Address
Enter the desired IP address for the AutoDome 800 Series in this field. The IP address must
be valid for the network. A typical IPv6 address may resemble the following example:
2001:db8 : : 52:1:1
Consult the network administrator for valid IPv6 address construction.
Prefix Length
A typical IPv6 node address consists of a prefix and an interface identifier (total 128 bits). The
prefix is the part of the address where the bits have fixed values or are the bits that define a
subnet.
Gateway Address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
7.49.3 Detailed Settings
DNS server address
The AutoDome 800 Series is easier to access if the unit is listed on a DNS server. If you wish,
for example, to establish an Internet connection to the AutoDome 800 Series, it is sufficient to
enter the name given to the unit on the DNS server as a URL in the browser. Enter the IP
address of the DNS server here. Servers are supported for secure and dynamic DNS.
Video Transmission
If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer
protocol. For use in a local network, select UDP.
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select Off.
HTTPS browser port
If you wish to allow browser access on the network via a secure connection, select an HTTPS
browser port from the list if necessary. The default HTTPS port is 443. Select the Off option
to deactivate HTTPS ports; only unsecured connections will now be possible.
The AutoDome 800 Series uses the TLS 1.0 encryption protocol. You may have to activate this
protocol via your browser configuration. You must also activate the protocol for the Java
applications (via the Java control panel in the Windows control panel).
CAUTION!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections.
The MTU value in UDP mode is 1,514 bytes.
NOTICE!
If you want to allow only secure connections with SSL encryption, you must select the Off
option for each of the parameters HTTP browser port, RCP+ port 1756 and Telnet support.
This deactivates all unsecured connections. Connections will then only be possible via the
HTTPS port.