45
Note :
●
When the [FULL AUTO] switch on the camera recorder is set
to
A
ON
B
, the recording level cannot be adjusted with the
[AUDIO LEVEL CH-1/CH-2] adjustment knob.
ⅥAutomatic Adjustment Mode
Set the [AUDIO SELECT CH-1/CH-2] switch on the camera
recorder to AAUTOB or the [FULL AUTO] switch to AONB to
enter Automatic Adjustment Mode. The audio recording level
is set automatically according to the input level.
When the [FULL AUTO] switch is set to AONB, mode
switching with the [AUDIO SELECT CH-1/CH-2] switch is
disabled.
Memo :
●
When [Audio] in the [Camera Function]
B
[FULL AUTO...]
menu is set to
A
SW Set
B
, you can switch the recording level
mode with the [AUDIO SELECT CH-1/CH-2] switch on the
camera recorder even if the [FULL AUTO] switch is set to
A
ON
B
. (
A
Page 75)
Audio Monitor During Recording
You can check the input audio with the monitor speaker or
earphones.
1 Select the channel to monitor with the [MONITOR
SELECT] switch.
2 Adjust the volume of the monitor audio with the
[MONITOR] adjustment knob.
Memo :
●
Alarm tone is output when there is an abnormality in the
camera recorder. Alarm tone is also output when the SDHC
card is full or when the battery is low.
Note :
●
Increasing the volume of the monitor too much may result in
howling of the camera microphone.
ⅥUsing Stereo Type Earphone Jack
When a stereo type earphone jack is connected, perform the
following setting to output stereo sound.
1 Set the [MONITOR SELECT] switch to ABOTHB.
2 Set [Main Menu]B[A/V Out]B[Audio Monitor] to
AStereoB. (A Page 87)
Only audio from [CH-1] is output through the monitor
speaker.
Memo :
●
You can set the volume of the alarm tone with [Alarm Level]
in the [Main Menu]
B
[Others] menu. (
A
Off
B
/
A
Low
B
/
A
Middle
B
/
A
High
B
) (
A
Page 87)
[CH-1] Outputs audio from [INPUT1] terminal.
[BOTH] Mixes and outputs audio from both [INPUT1/INPUT2]
terminals.
[CH-2] Outputs audio from [INPUT2] terminal.
[MONITOR]
Adjustment Knob
[MONITOR SELECT]
Switch
Monitor
Speaker
[PHONES]
Ter minal