49
C Max. Interval Enabled when both the first and second triggers are specified.
Specify the maximum interval between the first and second triggers. An
action will be invoked only if the interval between the first and second
triggers is within the maximum interval.
[Setting range : 1sec to 3600sec]
D 2nd Trigger This item specifies the second trigger to the operation set in [Action] A.
[Setting values :Off, Input 1 Make, Input 2 Make, Input 1 Break,
Input 2 Break]
E Action Position
No.
This item sets the position number to be moved when APositionB is
selected in [Action] A.
[Setting range : 0 to 99]
F Trigger Position
No.
This item sets the position number for trigger when APositionB is selected in
[1st Trigger] B.
[Setting range : 0 to 99]
G Mail Mail Address : For entering the recipient’s mail address.
Mail Text : For entering the mail transmission data. Input up to 127
alphanumeric characters.
Attach Image : For specifying whether to attach images to the mail.
H TCP/UDP
TCP/UDP IP Address
: For entering the address when alarm action notification is to be sent via
TCP or UDP. (IP or FQDN)
TCP/UDP Port Number
: For entering the port number when alarm action notification is to be sent
via TCP or UDP. (1-65535)
TCP/UDP Data
: For entering the data to send during TCP or UDP notification. Input up to
127 alphanumeric characters.
I Alarm Output
Duration
For setting the alarm output time from the alarm output terminal.
When this is set to A0B, it is not possible to revert back to break (or make)
after changing to make (or break).
[Setting range : 0/100msec to 5000msec]
J Time Filter For specifying the alarm action with respect to each day of the week and
setting the corresponding time of the day.
Applicable day of week
: Sunday, Monday, Tuesday, Wednesday, Thursday, Friday,
Saturday
Alarm action : Mask span
Unmask span
Mask All
Unmask All
Applicable time period
:
For specifying the Start and End time in hours and minutes.
VN-V686WPU_EN.book Page 49 Friday, February 8, 2008 5:20 PM