Olympus E-410 Digital Camera User Manual


 
EN
119
Information
9
Exposure control
Metering system : TTL full-aperture metering system
(1) Digital ESP metering
(2) Center weighted averaging metering
(3) Spot metering (approx. 2 % for the viewfinder screen)
Metering range : EV 1 - 20 (Digital ESP metering, Center weighted average metering,
Spot metering)
(At normal temperature, 50 mm F2, ISO 100)
Exposure mode : (1) AUTO: Fully automatic
(2) P : Program AE (Program shift can be performed)
(3) A : Aperture priority AE
(4) S : Shutter priority AE
(5) M : Manual
ISO sensitivity : 100 - 1600
Exposure compensation : ± 5 EV (1/3 EV step)
White balance
Product type : Image pickup device
Mode setting : Auto, Preset WB (7 settings), Customized WB, One-touch WB
Recording
Memory : CF card (Compatible with Type I and II)
Microdrive (Compatible with FAT 16/32)
xD-Picture Card
Recording system : Digital recording, JPEG (in accordance with Design rule for Camera
File system (DCF)), RAW Data
Applicable standards : Exif 2.2, Digital Print Order Format (DPOF), PRINT Image Matching
III, PictBridge
Playback
Playback mode : Single-frame playback, Close-up playback, Index display, Image
rotation, Slideshow, Calendar display
Information display : Information display, Histogram display
Drive
Drive mode : Single-frame shooting, Sequential shooting, Self-timer, Remote
control
Sequential shooting : 3 frames/sec. (Max. no. of storable sequential pictures: 6 frames in
RAW)
Self-timer : Operation time: 12 sec., 2 sec.
Optical remote control : Operation time: 2 sec., 0 sec. (instantaneous shooting)
(RM-1 Remote Control (optional))
Flash
Synchronization : Synchronized with the camera at 1/180 sec. or less
Flash control mode : TTL-AUTO (TTL pre-flash mode), AUTO, MANUAL
External flash attachment : Hot shoe
External connector
USB connector/VIDEO OUT connector (Multi-connector)
Power supply
Battery : Li-ion Battery (BLS-1) ×1
Dimensions/weight
Dimensions : 129.5 mm (W) × 91 mm (H) × 53 mm (D)
(5.1" × 3.6" × 2.1") (excluding protrusions)
Weight : Approx. 375 g (0.8 Ib.) (without battery)
Operating environment
Temperature : 0 m - 40 m (32 n - 104 n) (operation)/
-20 m - 60 m (-4 n - 140 n) (storage)
Humidity : 30 - 90 % (operation)/10 - 90 % (storage)
s0013_e_00_unified.book Page 119 Monday, March 5, 2007 10:04 AM