TEMPERATURE, HUMIDITY AND ALTITUDE
The following table lists the LF 6600 operating, storage and transit limits for temperature, humidity and
altitude.
Temperature, Humidity and Altitude Limits
1 Storage specifications are for 90 days maximum in Plasmon LMS packaging. No condensation is permitted. Transit specifications are
based on a maximum 1-week period in a factory-sealed container.
2 Maximum operating temperature is 42 _C for a free-standing drive at sea level unless otherwise stated. Maximum operating temperature
is derated linearly above 300 m altitude to 38 _C at 2,000 m altitude.
3 See the LD 6100/LF 6600/LF 6602 Product Specification (P/N 97653977) for more information concerning the temperature and humidity
operating range.
4 Media is limited to 2000 m. For conditions and limits pertaining to the media, refer to the LM 6000 Media Specification (P/N
97647044).
CONDITION OPERATING NONOPERATING
STORAGE/TRANSIT
1
Temperature
10 to 42° C
2
(50 to 108° F)
-40 to 66° C
-40 to 151° F)
-40 to 66° C
-40 to 151° F)
Maximum Rate of
Change
11° C/hr (20° F/hr) 20° C/hr (36° F/hr) 20° C/hr (36° F/hr)
Humidity
(Noncondensing
10 to 99% 5 to 95% 5 to 95%
Maximum Rate of
Change
10%/hr 10%/hr 10%/hr
Maximum Wet Bulb
Temperature
3
28° C (82° F) 46° C (115° F) 46° C (115° F)
Minimum Dew Point
C (35.6° F)
C (35.6°
0
F)
C (35.6° F)
Altitude
4
Storage:
-300 to 3,000 m
(-984 to 9,840 ft)
Transit:
-300 to 2,000 m
(-984 to 6,562 ft)
with media
-300 to 3,000 m
(0984 to 9840 ft)
Storage:
-300 to 3,000 m
(984 to 9,840 ft)
Transit:
-300 to 12,000 m
(-984 to 40,000 ft)