NOTE
You must first determine the type of termination your host system
requires (see the Accessories Section of this Manual).
In a daisy chain configuration, a terminator must be used on both the first and last devices on the bus.
One of these devices may be the host adapter. All other LF 6600's between the first and last device in the
daisy chain should not be terminated.
NOTE
Installation of both an active single-ended terminator and a passive
single-ended terminator on the same bus is not recommended.
If only one LF 6600 is attached to a host, the bus must be terminated at the host adapter and the LF 6600.
Normally, the termination function is built into the host adapter. Power for the external terminator is
supplied from the LF 6600 and may also be supplied from another device in the SCSI daisy chain.
Terminator power for external terminators is provided by the LF 6600 power supply.
EP004237
LF 6600-to-Host Cable Connection
Refer to the Accessories Section of this manual for a list of SCSI bus terminators, cables and their
Plasmon LMS part numbers.