SETTING THE CONFIGURATION OF THE OPERATING PARAMETERS ("SET CONFIG")
To enter the mode to set the drive configuration, press the TEST/SELECT switch while "Set Config" is
displayed in the Main menu. The drive will enter the Set Configuration menu which includes the following
options:
"Set Defaults"
Press the SELECT switch to set all drive operating parameters to the factory
defaults. Press the MENU switch to select the next option in the Set
Configuration menu.
"SCSI ID:"
Press the SELECT switch to scroll through the possible SCSI ID values
(0,1,2,3,4,5,6,7). When the desired ID value is displayed, press the MENU
switch to enter that value as the SCSI ID and select the next option in the Set
Configuration menu.
"Parity:"
Press the SELECT switch to turn parity checking on or off. SCSI bus parity
generation is always enabled but SCSI bus parity checking by the drive may
be turned on or off. When the desired state (on or off) is displayed, press the
MENU switch to enter that state for parity checking and select the next option
in the Set Configuration menu.
"Language:"
Press the SELECT switch to scroll through the language options (Eng =
English, Frh = French, Grm = German) for the DOC operating messages.
When the desired language option is displayed, press the MENU switch to
enter that option and select the next option in the Set Configuration menu.
"Wrt Prot:"
Press the SELECT switch to turn write protect on or off. When the desired
state (on or off) is displayed, press the MENU switch to enter that state for
write protect and select the next option in the Set Configuration menu.
"AutoLoad:"
Press the SELECT switch to scroll through the Auto Load options. The drive
can be configured to load the cartridge residing in a specific slot (1,2,3,4,5,6)
or the Most Recently Used (MRU) cartridge. When the desired option
(1,2,3,4,5,6,MRU) is displayed, press the MENU switch to enable that option
and select the next option in the Set Configuration menu.
"Load SW:"
Press the SELECT switch to enable or disable the LOAD switch on the DOC.
When the desired state (on or off) is displayed, press the MENU switch to
enter that state for load switch and select the next option in the Set
Configuration menu.
"Rd Ahead:"
Press the SELECT switch to turn read ahead on or off. When the desired
state (on or off) is displayed, press the MENU switch to enter that state for
read ahead and select the next option in the Set Configuration menu.
"CDE Curs:"
Press the SELECT switch to turn the CDE indicator (a blinking solid cursor in
the rightmost display position) on or off. When the desired state (on or off) is
displayed, press the MENU switch to enter that state for CDE Curs and select
the next option in the Set Configuration Menu.