Plasmon LF6600 Camcorder User Manual


 
PLASMON LASER MAGNETIC STORAGE - LF 6600 User Manual
Page 60
3) Set the AC Power Switch to the ON ( I ) position and verify that air is flowing through the
LF 6600.
4) Verify that the WRITE PROTECT indicator is illuminated briefly.
5) Verify that the "Selftest" message is displayed on the DOC.
The "Selftest" message indicates that the power-on selftests are running. When the power-on selftests
have run without errors, the drive will perform a test to determine which slots in the shuttle are occupied by
media cartridges and then will load media number 1.
When the "1 Ready" message is displayed, the LF 6600 has passed the power-on selftests and has
successfully loaded the LM 6000 media cartridge in slot 1.
6) Verify that the "Selftest" message displayed on the DOC is replaced by the "1 Ready"
message.
7) Refer to the Modes of Operation section of this manual to familiarize yourself with the LF
6600 modes of operation.
The LF 6600 is now in the normal Operating mode, and is ready to be controlled and accessed by a host
system.
MODES OF OPERATION
The LF 6600 has three modes of operation that are selectable from the DOC:
Operating Mode
Configuration Mode
Test Mode
In Operating mode the host system can read and write data, and select and load media cartridges. In
Configuration mode an operator can view a menu of parameters and select options for each parameter.
Test mode invokes drive diagnostics to verify proper drive operation.
OPERATING MODE
The LF 6600 enters the Operating mode after being powered on and displays the "# Ready" message on
the DOC. The DOC will display the appropriate messages listed in the next table during normal operation.
To enter Operating mode if the drive is in Test mode, wait until the tests are completed and then press the
LOAD/MENU switch. To enter Operating mode if the drive is in Configuration mode, press the LOAD/
MENU and the TEST/SELECT switches simultaneously.