Plasmon LF6600 Camcorder User Manual


 
PLASMON LASER MAGNETIC STORAGE - LF 6600 User Manual
Page 78
Diagnostics Selftests
"Sys Log:" Press the SELECT switch to enable or disable system event logging. The log
can be used by a trained CE to help in problem isolation or for performance
monitoring. Drive performance will be slowed and may not meet specification
if logging is enabled. The default is "Sys Log Off". Press the MENU switch to
select the next option in the Diagnostics Menu.
"Test Thru:" Press the SELECT switch to set the level of diagnostics tests which will be
performed during selftest (refer to the next table). Selftest is invoked by
pressing the TEST switch on the DOC panel.
Tests always start at test 0 and continue through the test number selected by
the "Test Thru:" option. For example, if test 5 is selected ("Test Thru:5"),
selftest diagnostics will include tests 0 through 5. This selftest series will be
performed each time the TEST switch is pressed.
Press the MENU switch to select the next option in the Diagnostics Menu.
TEST # DESCRIPTION OF TEST
0 Power-on self-test. This test cannot be disabled; it runs
automatically when the drive is powered on.
1 PCA Self-tests, DPR Communication
2 Read/Write Data Path
3 OMA
4 Cartridge Guide and Shuttle Sensors
5 Baseplate and Spindle Motor Operation
6 Servo Control Systems
7 Read Performance
8 Write Performance, Write Power Calibration
9 Reserved
"View RTPM" Press the SELECT switch to view the RTPM (Real Time Performance
Monitor) status. If no RTPM error has occurred, the DOC will display "No
RTPM Err". If an RTPM error has occurred, the DOC will display the media
serial number and drive channel combination which caused the RTPM error.
The media serial number will be displayed for 5 sec (S/N: ########) and
then the drive channel will be displayed for 4 sec (Channel: A, B, or A+B).
The display will then return to the View RTPM option.