4-28 Chapter 4 Adjustments and Settings for Recording
4
4 If you are using the DNW-7/90/90WS/9WS, set the DF/NDF switch.
DF: Drop frame mode
NDF: Non-drop frame mode
5 Using the SHIFT and ADVANCE buttons, set the time code.
SHIFT: Selects a digit to set. Each time you press it, the flashing
column moves to the right one digit.
Pressing this button while holding down the HOLD button moves
the flashing digit one to the left.
ADVANCE: Increments the flashing digit.
Pressing this button while holding down the HOLD button
decrements the flashing digit.
6 Set the F-RUN/SET/R-RUN switch to F-RUN or R-RUN.
F-RUN: Free run - The time code advances constantly.
R-RUN: Record run - The time code stops except during recording.
Making the time code continuous
When the F-RUN/SET/R-RUN switch is set to R-RUN, recording a
number of scenes on the tape normally produces continuous time codes.
If, however, you take the cassette out at some point, the time code will
no longer be continuous.
To make the time code continuous, follow the procedure below.
1 Set the PRESET/REGEN/CLOCK switch to REGEN.
2 Use the tape transport buttons to play back.
3 Watching the playback, find the point of the previous recording on
the tape from which you wish to continue recording, and press the
STOP button.