Sony DNW-90/90P Camcorder User Manual


 
Chapter 6 Maintenance 6-3
6
Testing the viewfinder
1 Adjust the position of the viewfinder.
2 Check that the color bars are displayed in the viewfinder, and adjust
the BRIGHT, CONTRAST, and PEAKING controls to give the best
color bar display.
3 (1) Set the MENU ON/OFF/PAGE switch to ON and check that the
setup menu is displayed on the viewfinder screen.
(2) Push the MENU ON/OFF/PAGE switch to PAGE and check that
the setup menu page changes to the next page.
(3) Push the MENU CANCEL/PRST/ITEM switch to ITEM and
check that the cursor moves within the current page.
(4) Turn the rotary encoder and check that the setting value or ON/
OFF indication of the item selected by the cursor changes.
4 After once setting the MENU ON/OFF/PAGE switch to OFF, set the
OUTPUT/DCC selector to CAM, and change the FILTER selector
position in the sequence of 1, 2 , 3, 4. Check that the FILTER
indicator on the viewfinder screen displays the correct numbers.
5 Check each of the following operations, and make sure that the
indicator lights if the corresponding item has been turned on in the
‘!’ LED page.
(1) Set the gain to anything but 0 dB by the GAIN selector and on
the MASTER GAIN page of the setup menu.
(2) Set the SHUTTER selector to ON.
(3) Set the WHITE BAL switch to PRST.
(4) Use the lens extender.
(5) Set the two-part FILTER selector to anything but 1.
(6) Set the iris to automatic mode, and turn the rotary encoder to
change the reference value to other than the standard value.
(Continued)