Sony F23 Camcorder User Manual


 
67
Menu List
Chapter 4 Menu Configuration and Detailed Settings
<AUTO IRIS>
Auto iris adjustment
M06 AUTO IRIS OFF ON, OFF
WINDOW 1 1, 2, 3, 4, 5, 6 Select the auto iris
windows:
The shaded parts indicate
the area where light
detection occurs.
OVERRIDE 0 99 to +99 To set the override to
temporarily change the
reference value for
brightness of the automatic
iris level, in the range of ±2
steps:
–99: Two steps to fully
closed iris
+99: Two steps to fully open
iris
The setting returns to “0”
when the power is turned
off.
IRIS LEVEL 0 99 to +99 ±4 steps
APL RATIO 65 99 to +99 To adjust the response of
the iris for high-luminance
subjects
IRIS GAIN 0 99 to +99 To adjust the iris operation
sensitivity
IRIS CLOSE OFF ON, OFF
<OUTPUT
FORMAT>
Setting the output
video format
M07 CURRENT 23.98PsF 4:4:4 The current format is
displayed.
SCAN PROGRESSIVE PROGRESSIVE,
INTERLACE
When INTERLACE is
selected for SCAN, select
half the value of the field
frequency in FRAME.
FRAME 23.98 23.98, 24, 25, 29.97, 30,
50, 59.94, 60
SIGNAL 4:4:4 RGB 4:4:4 RGB, 4:2:2 YCbCr
SELECT FPS OFF ON, OFF
SET FORMAT Execute by ENTER.
<DOWN
CONVERTER>
Setting the aspect
ratio for VBS output
M08 ASPECT SQ SQ, EC SQ: Squeeze
EC: Edge Crop
<POWER SAVE>
Selecting the output
power save mode
M09 MONITOR OUT ACTIVE PWR SAVE, ACTIVE
DOWN CONVERTER ACTIVE PWR SAVE, ACTIVE
MAINTENANCE menu
Page title &
purpose
No. Item Default Settings Remarks
123
456