TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)
©TOSHIBA Corp.
42
3.2 Bandwidth Control Settings
wbsetnwkbandwidth.cgi
3.2.1 Syntax
1) http://<camip>/api/wbsetnwkbandwidth.cgi?type=Default
2) http://<camip>/api/wbsetnwkbandwidth.cgi?type=Set[&Mode=<value>][&Numeric=<value>][&BandWidth=<value>]
3.2.2 Input
Item Type Entry name Entry value Std.val Unit
Reset to Default type=Default - - - -
Function Mode 1:OFF 2:ON 1 -
Band numeric Numeric any (0<n<=102400) 100 -
Band unit
type=Set
BandWidth 1:Kbit/S 2:Mbit/S 2 -
Log output control of cgi common to all types OpeLog No/Yes [default: Yes] (omissible) - -
3.2.3 Output
Code Status Code Status Code Status
20 OK 32 InvalidValue 92 CriticalError
30 InvalidType 33 InvalidOperand
31 InvalidEntr
y
34 NoEntryData
3.2.4 Example
1) http://10.1.0.1/api/wbsetnwkbandwidth.cgi?type=Default
2) http://10.1.0.1/api/wbsetnwkbandwidth.cgi?type=Set&Mode=2&Numeric=256&BandWidth=1
3.2.5 Notes
1) If only type=<value> is entered and then <entry>=<value> is not entered, no setting is performed. (type=Default is an exception.)
2) Multiple type=<value> cannot be enumerated simultaneously. This API must be started for each type.
3) For only entered items, setting is performed. For the other items, their existing values are held.