Toshiba Toshiba Security Camera User Manual


 
TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)
©TOSHIBA Corp.
79
9.4 Reference of Recording Settings
wbgetcamrecord.cgi
9.4.1 Syntax
1) http://<camip>/api/wbgetcamrecord.cgi
9.4.2 Input
Item Type Entry name Value
Log output control of cgi common to all types OpeLog No/Yes [default: Yes] (omissible)
9.4.3 Output
Code Status Code Status
20 OK 92 CriticalErro
r
32 InvalidValue
33 InvalidOperand
wbgetcamrecord.cgi indicates the notification data format to the client when data has been obtained normally.
20 OK\r\n
\r\n
[Camera-Recording]\r\n
<Alarm>\r\n
AlarmInRecMode (value)\r\n
ExtControlInRecMode (value)\r\n
MotionRecMode (value)\r\n
NumberOfPrePicture (value)\r\n
NumberOfPostPicture (value)\r\n
Interval (value)\r\n
<Normal>\r\n
Mode (value)\r\n
Monday (value)\r\n
Tuesday (value)\r\n
Wednesday (value)\r\n
Thursday (value)\r\n
Friday (value)\r\n
Saturday (value)\r\n
Sunday (value)\r\n
Pattern1Start (value)\r\n
Pattern1End (value)\r\n
Pattern2Start (value)\r\n
Pattern2End (value)\r\n
Interval (value)\r\n
<RecOverwriting>
Mode (value)\r\n
9.4.4 Example
1) http://10.1.0.1/api/wbgetcamrecord.cgi
9.4.5 Notes
1) When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.