Toshiba Toshiba Security Camera User Manual


 
TOSHIBA Network Camera - IK-WB15A - SDK (Ver 1.00.SC)
©TOSHIBA Corp.
43
3.3 DDNS Settings
wbsetnwkddns.cgi
3.3.1 Syntax
1) http://<camip>/api/wbsetnwkddns.cgi?type=Default
2) http://<camip>/api/wbsetnwkddns.cgi?type=Set[&Mode=<value>][&Server=<value>][&...]
3.3.2 Input
Item Type Entry name Entry value Std.val Unit
Reset to Default type=Default - - - -
DDNS mode Mode 1:OFF 2:ON 1 -
DDNS server Server any (max.128 bytes) -
User ID UserID any (max.32 bytes) -
Password
type=Set
Password any (max.32 bytes) -
Log output control of cgi common to all types OpeLog No/Yes [default: Yes] (omissible) - -
3.3.3 Output
Code Status Code Status Code Status
32 OK 32 InvalidValue 92 CriticalErro
r
30 InvalidType 33 InvalidOperand
31 InvalidEntr
y
34 NoEntryData
3.3.4 Example
1) http://10.1.0.1/api/wbsetnwkddns.cgi?type=Default
2) http://10.1.0.1/api/wbsetnwkddns.cgi?type=Set&Mode=2&UserID=<base64enc>&Password=<base64enc>
3.3.5 Notes
1) If only type=<value> is entered and then <entry>=<value> is not entered, no setting is performed. (type=Default is an exception.)
2) Multiple type=<value> cannot be enumerated simultaneously. This API must be started for each type.
3) When LoginID/Password is specified, these must be base64-encoded.
4) When a blank character is included in <value>, it must be URL-encoded.
5) For only entered items, setting is performed. For the other items, their existing values are held.
6) When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.