B&K 8510 Digital Camera User Manual


 
15
10A
5A
Continuous Transient Operation
2.0ms 3.0ms
Pulse
Switch to value B upon receiving one trigger signal , after taking the pulse time(TWD) of value B, the load will return to
Value A .
10A
5A
Pulsed Transient Operation
10ms
TWD
10ms
TWD
TRIG TRIG
Trigger Mode
Switches the state between value A and value B once trigger signal is received.
10A
5A
TRG
TRG
Toggled Transient Operation
List Operation
List mode lets you generate complex sequences of input changes with rapid, precise timing, which may be synchronized with
internal or external signals. List operation can be changed by editing every step value and time in list operation. The
parameter of list operation include the group file name, input step setting (the max steps is 1000 steps),time of one step
1mS~6000mSand setting value of one step. In CC mode, dwell time range is 1mS to 6S, which also have an associated
value. Note that lists data can only be saved in total 1000 steps memory of 4 situations.