B&K 8510 Digital Camera User Manual


 
17
Input On/Off
Electronic load's input can be toggled on/off at the front panel. Turning the input off (zero current) does not affect the
programmed settings. The input will return to the previously programmed values when the input is turned on again.
NOTE
The Input On/Off command supersedes the mode commands and Short Test
On/Off command.
Operation Range
Work in the range of Rated Current, Rated voltage and Rated Power, The figure is as following:
INPUT VOLTAGE V
Rated voltage
Rated power
Input current I Rated current
Operation mode change state
INPUT VOLTAGE V
Rated voltage
Software Power Limit
Input current I Rated current
Software Current Limi
t
C
A
Protection Features
This Electronic Load includes the following protection features:
Over Voltage
If input voltage exceeds the voltage limit, Load will turn OFF the input and a buzzer turns on. VFD displays the
following:
Over Current
OVER VOLTAGE