Canon VB101 Security Camera User Manual


 
152
Message
Explanation
S001 Ethernet interface initialization failed (crit)
eci: netif can't up
Network interface initialization failed.
Response
If rebooting does not resolve the problem, contact an authorized Canon service representative.
Message
Explanation
S002 Ethernet route registration failure (err)
eci: net route can't add
An attempt to register a route for a local Ethernet segment failed.
Response
Correct the Ethernet settings and reboot.
Message
Explanation
S003 Ethernet default route registration failed (err)
eci: default route can't add
Registration of the default Ethernet route failed.
Response
Correct the Ethernet settings and reboot.
Message
Explanation
S006 IP address conflict detection at startup (err)
Detected a conflict for IP address %1 with %2
An IP address conflict was detected during startup. If there is a device running on the network that
has the same IP address as the VB101, this error occurs when the VB101 starts up.
%1
IP address
%2
Ethernet address
Response
Change the VB101 IP address or change the IP address of the conflicting network
device. If you change the VB101 IP address, the VB101 must be rebooted.
When there is an IP address conflict, it may not be possible to modify the settings
via Ethernet. In this event, an initial setup tool must be used to change the settings.
System-related Log Messages
Log Messages
Message
Explanation
S004 System startup (info)
System started
The VB software started up.
Message
Explanation
S005 System settings changed (info)
System settings updated
The VB software settings were modified without a reboot.