Celestron SPX900 Camcorder User Manual


 
106
8-5-8 IRIS
8-6 MAIN OPERATION
8-6-1 BATTERY/P2CARD
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved
Adjustable
Range
Remarks
A.IRIS LEVEL 000
:
050
:
100
Set the target value for auto iris.
–CUFE
A.IRIS PEAK/
AVE
000
:
040
:
100
Determine the peak-to-standard ratio for the
auto iris.
A larger value sets the auto iris to respond to
the peak in the IRIS detection window, while
a smaller value sets it to respond to the
average value in the window.
–CUFE
A.IRIS MODE NORM1
NORM2
CENTR
Select the auto iris detection window.
NORM1
:The window closer to the center of
the screen.
NORM2
:The window closer to bottom of the
screen.
CENTR
:The spot window in the center of the
screen.
–CUFE
S.IRIS LEVEL 000
:
080
:
100
Set the target value for the super iris.
–CUFE
IRIS GAIN CAM
LENS
Select which unit controls IRIS GAIN.
<Note>
Lenses with an extender, such asC2, C0.8
sold before FUJINON DIGI POWER,
perform IRIS compensation while enabling
the extender. Therefore, if this setting is
switched to CAM, the camera’s iris control
will not operate properly.
–CUFE
IRIS GAIN
VALUE
01
:
08
:
20
Set the adjustable value for IRIS GAIN. This
setting is effective when CAM is selected for
IRIS GAIN.
–CUFE
Items/
Data Saved
Adjustable
Range
Remarks
BATTERY
SELECT
PRO14
TRIM14
HYTRN50
HYTRN100
HYTRN120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Select the battery to use. Remaining
capacity detection is also performed
according to the selected battery.
The selectable battery types change
depending on the settings under [8-6-2
BATTERY SETTING1] and [8-6-3 BATTERY
SETTING2].
–CUF–
EXT DC IN
SELECT
AC_ADPT
PRO14
TRIM14
HYTRN50
HYTRN100
HYTRN120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Set the remaining capacity detection type
when a battery is connected to the DC IN
connector. Remaining capacity detection is
also performed according to the selected
battery type.
The selectable battery types change
depending on the settings under [8-6-2
BATTERY SETTING1] and [8-6-3 BATTERY
SETTING2].
<Note>
The % display is disabled even when a
digital battery is connected to the DC IN
connector.
–CUF–
BATT NEAR
END ALARM
ON
OFF
Select whether or not to set the alarm to
beep for BATT NEAR END ALARM.
–CUF–
BATT NEAR
END CANCEL
ON
OFF
If set to ON, the warning tone and indication
can be canceled by pressing the MODE
CHECK button when BATT NEAR END
ALARM is triggered.
–CUF–
BATT END
ALARM
ON
OFF
Select whether or not to set the alarm to
beep for BATT END ALARM.
–CUF–
BATT REMAIN
FULL
100%
70%
Set the display content of the remaining
battery capacity indicator bars in the display
window when using a digital battery.
100%:
Indicate FULL at 100% capacity.
70%: Indicate FULL at 70% capacity.
–CUF–