10. TIME CODE OPERATION
10-1 Displaying Time Code
The GY-DV5000 records SMPTE-standard time codes and user’s bits. In the play mode or the record mode, the reproduced time
codes or user’s bits are shown on the LCD monitor or in the viewfinder.
Time code data cannot be output through the unit’s connectors.
OPEN
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
AUDIO
LEVEL
CH-1 CH-2
PULL
OPEN
LCDBRIGHT DISPLAY
COUNTER
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
TC GENE.
TC
MONITOR
SELECT
AUDIO
LEVEL
AUDIO INPUT
CH-1 CH-2
CH-1
MIX
CH-2
FRONT REAR
LINE
MIC
+48V
PRST
REGEN FREE
REC
UB
LCDBRIGHT DISPLAY
OPEN
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
AUDIO
LEVEL
CH-1 CH-2
PULL
OPEN
LCDBRIGHT DISPLAY
COUNTER
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
TC GENE.
TC
MONITOR
SELECT
AUDIO
LEVEL
AUDIO INPUT
CH-1 CH-2
CH-1
MIX
CH-2
FRONT REAR
LINE
MIC
+48V
PRST
REGEN FREE
REC
UB
LCDBRIGHT DISPLAY
TC00:00:00:00
STBY 01/02/03 01:23:45
––– TC/UB/CLOCK –––
TC PRESET 00:00:00:00
EXECUTE
TC CLEAR CANCEL
UB PRESET 00 00 00 00
EXECUTE
UB CLEAR CANCEL
DROP/NON DROP DROP
TIME/DATE..
PAGE BACK
The time codes or user’s bits can be shown on the LCD monitor
or in the viewfinder during playback and recording as follows.
(Status screen)
Setting
1.
Set the TC/UB item on the LCD/VF (2/2) menu screen to
ON.
Time codes or user’s bit data are displayed on the Status
screen.
2.
Whether time codes or user’s bit data should be displayed
is selected with the COUNTER switch inside the cover on
the side.
TC : Time codes are displayed.
The symbol between the seconds and the frame
differs with the framing mode. (Colon or dot)
UB : User’s bit data is displayed.
COUNTER switch
Time code indication
Status 1 screen
10-2 Presetting and Recording of Time Code
To preset the Time Code, make the following settings.
TC GENE. switch
Set to PRESET REC or PRESET FREE.
PRST REC : The data preset in the time code generator
runs only during recording.
Use this setting if it is necessary to record
continual time codes across different scenes.
*However, approximately ±1-frame variations
may occur in scene accuracy.
PRST FREE : The time code starts to run from the time it is
preset in the time code generator.
TC/UB/CLOCK menu screen
Use the DROP/NON DROP item to select the framing mode
for the time code generator.
DROP : The time code generator’s running method is
set to the drop frame mode.
Use this setting when placing emphasis on
the recording time.
NON DROP : The time code generator’s running method is
set to the non drop frame mode.
Use this setting when placing emphasis on
the number of frames.
Example
Time code indication
00:00:00:00
Non-drop frame (:)
Drop frame (.)
User’s bits indication
FF EE DD 20
Framing mode:
Non-drop/Drop setting
TC GENE. switch
TC/UB/CLOCK menu screen
Drop frame/Non-drop frame mode
In the NTSC system, the actual number of frames per 1 second is approximately 29.97 frames, but per time code 30 frames are
processed. To compensate for this difference, the mode called “drop mode” drops frame 00 and 01 for every minute not divisible
by 10.
The “non-drop frame mode” is when no frames are dropped and the actual time shift is neglected.
The time codes or user’s bit data from the internal time code generator can be recorded at the time of recording scenes.
(U model)
63
10. TIME CODE OPERATION
––– MENU –––
CAMERA OPERATION..
CAMERA PROCESS..
AUDIO/VIDEO..
LCD/VF..
TC/UB/CLOCK..
OTHERS..
FILE MANAGE..
MENU ALL RESET CANCEL
EXIT
––– TC/UB/CLOCK –––
TC PRESET 00:00:00:00
EXECUTE
TC CLEAR CANCEL
UB PRESET 00 00 00 00
EXECUTE
UB CLEAR CANCEL
DROP/NON DROP DROP
TIME/DATE..
PAGE BACK
––– TC/UB/CLOCK –––
TC PRESET 00:00:00:00
EXECUTE
TC CLEAR CANCEL
UB PRESET 00 00 00 00
EXECUTE
UB CLEAR CANCEL
DROP/NON DROP DROP
TIME/DATE..
PAGE BACK
Align the cursor with UB
TIME CODE PRESETTING PROCEDURE
The time code and user’s bit data are preset on the TC/UB/
CLOCK menu screen.
1.
Display the TC/UB/CLOCK menu screen.
1 Press the Status button for 1 second or more to display
the TOP MENU screen.
2 Rotate the SHUTTER dial to align the cursor (
) with
the TC/UB/CLOCK item, and then press the SHUTTER
dial.
The TC/UB/CLOCK menu screen appears.
2.
Set the time code (hours, minutes, seconds, frames).
1 Rotate the SHUTTER dial to align the cursor (
) with TC
PRESET, and then press the SHUTTER dial.
The first digit of the time code blinks.
The blinking digit is the one to be set.
2 When the SHUTTER dial is pressed, the blinking digit
changes.
3 When the SHUTTER dial is rotated, the value of the
blinking digit changes.
When the SHUTTER dial is rotated upward, the value
becomes higher. When rotated downward, the value
becomes smaller.
4 Repeat the procedure described in 2 and 3 above to
set the desired value for all digits.
5 After setting the frame digit, press the SHUTTER dial to
make EXECUTE blink. The setting values are confirmed
when the SHUTTER dial is pressed again.
To cancel the setting, select CANCEL and press the
SHUTTER dial.
3.
When all the digits are set.
Press the STATUS button to return to the normal screen
or
Rotate the SHUTTER dial to align the cursor (
) with the
PAGE BACK item, and then press the SHUTTER dial to
return to the TOP MENU screen.
TOP MENU screen
TC/UB/CLOCK menu screen
Time code (hour, min, sec, frame)
PRESETTING USER’S BIT DATA
The user’s bit data are preset with the UB PRESET item on the
TC/UB/CLOCK menu screen.
The method for setting is the same as the method for setting
the time code described above.
The user’s bit can be specified using numerals or alphabetic
letters from 0 to F for each digit.
CAUTION:
Do not set all the digits of the user’s bit data to “F”. Reading
of the data during playback will not be possible for an all-F
setting.
MONITOR
EDITSEARCH
FILTER
STATUS
SHUTTER
MENU
AUTO IRIS
BACK L
NORMAL
SPOT L
STRETCH
NORMAL
COMPRESS
FULL AUTO BLACK LOLUX
MODE
POWER
ON OFF
VTR
OPEN
VTR
CAM
1
3200K
5600K
5600K
5600K
ND
/
/
ND
2
.3
.4
1
8
1
64
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
AUDIO
LEVEL
CH-1 CH-2
PULL
OPEN
LCDBRIGHT DISPLAY
SHUTTER dial STATUS button
Zero-resetting the Time Code or User’s Bit Data
This is performed with the CLEAR item on the TC/UB/CLOCK menu screen. (Performed separately for the time code and the
user’s bit data.)
1 Rotate the SHUTTER dial to align the cursor (
) with the CLEAR item, and then press the SHUTTER dial.
2 Rotate the SHUTTER dial to select EXECUTE as the setting value, and then press the SHUTTER dial.
(U model)