JVC LWT0254-001B-H Security Camera User Manual


 
32 EN
Setting Up the Camera Using RM-P2580 (continued)
MANUAL PAN LIMIT Setup
This section describes procedures for setting the Panning
(horizontal) range during manual operation.
1 Select a camera. (ARM-P2580 AINSTRUCTIONSB)
CAMERA buttonNNumeric key (Camera Number)NENTER button
Video images of the selected camera will be output.
2 MENU screen display. (A pg. 21, steps 2 to 4)
MENU button (3 sec.) N Select ACAMERA..B using the PAN lever N
SET button.
The AMENUB screen will be displayed.
3 Move the PAN lever upward/downward to shift the cursor (E)
to the ACAM. FUNCTION 2..B item, followed by pressing the
SET button.
The ACAMERA FUNCTION 2B screen will be displayed.
4 Shift the cursor (E) to the AM. PAN LIMIT..B item, and move
the PAN lever leftward/rightward to select AONB.
5 Press the SET button.
The AM. PAN LIMIT POS.SETB screen (left limit) will be displayed.
6 Set the position for the left limit.
Use the PAN lever to determine the position for the left limit.
During setting, a message indicating A[L] POS. SETTING NB will be
displayed at the bottom left of the screen.
7 Press the SET button.
The screen will switch to the right limit setting screen.
8 Set the position for the right limit.
Use the PAN lever to determine the position for the right limit.
During setting, a message indicating AO [R] POS. SETTINGB will be
displayed at the bottom right of the screen.
9 Press the MENU button.
This stores the limit positions that have been set and returns the
screen to the ACAMERA FUNCTION 2B menu.
MEMO
Tilting , zooming and focusing operations are possible when this menu is displayed.
If a pan limit has already been set, the camera will move to the left pan limit position
when this menu is invoked.
Setting cannot be performed when Panning is in progress. Press the SET button
after Panning has come to a stop.
Auto Flip operation will override this setting if the destination position of Auto Flip is
outside the range as set in this item.
Manual Pan Limit remains valid when setting preset positions.
Movement to preset positions will be performed without regard to the Manual Pan Limit.
The AM. PAN LIMIT..B item will not affect the following even when it is set to AONB.
•PRIVATE MASK Settings
•AUTO PAN POSITION Settings
•AREA DISPLAY Settings
SETUP
MENU SET
SPEED
IRIS
AF
FOCUS
ZOOM
OPEN
FAR
TELE CLEAR
/HOME
7
4
1
8
0
5
2
9
6
3
ENTER
AUTO
PAN
OPTION
1
OPTION
2
CAMERA
POSI-
TION
AUTO
PATROL
CLOSE
NEAR
WIDE
AUTO F-1 F-2 F-3
PAN/TILTLENS
CAMERA/POSITION
CAMERA POSITION
REMOTECONTROLUNIT
RM-P2580
ALARM
POWER
KEYLOCK
MENU button
CAMERA button
SET button
Numeric
keys
PAN lever
ENTER
button
CAMERA FUNCTION2
FLIP OFF
VAR.P/T SPEED ON
EASY AF OFF
AF FOR IR OFF
TILT LIMIT
M. PAN LIMIT.. ON
AUTO RETURN..
<
MENU
>
RETURN
<
SET
>
SUB MENU
CAMERA FUNCTION 2 Screen
M. PAN LIMIT POS.SET
<
SET
>
INVALID
DURING PAN MOVEMENT
<
MENU
>
RETURN
<
SET
>
L/R
[L]POS.SETTING
M. PAN LIMIT POS.SET Screen (Left Limit)
M. PAN LIMIT POS.SET
<
SET
>
INVALID
DURING PAN MOVEMENT
<
MENU
>
RETURN
<
SET
>
L/R
[R]POS.SETTING
M. PAN LIMIT POS.SET Screen (Right Limit)