JVC VN-C205 Digital Camera User Manual


 
42
1
Alarm 1/Alarm 2
Mode
Detect Mode
Alarm Output
Message Packet
Alarm FTP
Shutdown
Alarm Input
Item Function/Set Value
This section describes setting procedures for alarm input.
For selecting whether to enable or disable the input signals.
Set Values :Available, Not Available
For selecting the method for detecting input signals.
Make : Detect input signals at the "Make" contact point.
Break : Detect input signals during "Break".
Toggle : Detect input signals at both "Make" and "Break".
For selecting whether to output from the alarm output terminal
when there is alarm input.
Not Available :Do not output from the alarm output terminal.
Alarm Output 1
:
Send output from the Alarm Output 1 terminal.
Alarm Output 2
:
Send output from the Alarm Output 2 terminal.
For setting whether to send alarm packets to the PC when there
is alarm input.
Not Available : Do not send alarm packets.
Available : Send alarm packets.
For operation according to the [Alarm FTP] in the FTP Client
feature when there is alarm input. Please refer to FTP Client
Settings (
Page 50) for details on alarm FTP.
Set Values: Available, Not Available
Set to "Available" to quit all operations upon alarm input. Using
this Shutdown function enables operations of this camera to
end safely even during recording into CF cards.
Not Available : Do not shut down.
Available : Shut down.
2-4 Other Settings Using the "VN-C205U Setup Tool" (4. Alarm Setting) (Continued)
Settings (Step 2 Network Settings)
Initial Value
Not Available
Make
Not Available
Not Available
Not Available
Not Available
Note
Unless the alarm output in the "Alarm Output" tab is enabled,
this function will not be activated even if alarm output is
selected in the alarm input settings. (
Page 44)
Note
•When this is set to "Available", all alarm input except alarm
output and message packets will be disabled.
43
2
Relay Alarm
Alarm Output
Message Packet
• Alarm FTP
• Shutdown
3
Retry (1 to 3)
Item Function/Set Value
Set here to enable the relay alarm function, which is activated
when 2 alarms are received within a preset time interval.
The sequence and time interval for the alarm input can be specified.
When [Alarm Output] is selected, alarm signal output will be
sent to the alarm output terminal on the ceiling mount accord-
ing to the output port settings.
* Please refer to the [Alarm 1/2] item for details on the set val-
ues.
For setting the no. of times alarm notification is to be sent to
the "V.Networks Controller". (Set Value: 1 to 3)
Initial Value
Not Available
*
Please
refer to
the [Alarm
1/2] item
for the
initial
values.
1
Note
•Alarm notification may fail, depending on the LAN
environment in use. If it fails, set the value for alarm
notification to "3". In this case, alarm by the "V.Networks
Controller" itself is set off only once.
Notes
•Asecond alarm input enables this relay alarm function,
and alarm will not be activated for this second input.
•Unless the alarm output in the "Alarm Output" tab is
enabled, this function will not be activated even if alarm
output is selected in the alarm input settings. (
Page 44)
Press here to display the IP address of the PCs to which an
alarm notification is sent. ("Distribution Address List" Screen)
To delete a distribution address, select the IP address to de-
lete, followed by pressing the Delete button.
4
List
Notes
The list allows setting of up to 10 addresses.
Message packets will not be sent out when there are 11 or
more addresses.