The "V.Networks Controller" can be used to set the action to be taken when an
alarm signal is received.
1.
Select [Setting] and [Alarm Setting].
3-7 Alarm Setting
2.
Change the set values. (For description of each function,
next page)
Setting may be performed for the [Motion Detection], [Alarm 1], [Alarm 2], [Relay Alarm].
3.
When setting is complete, click .
1
2
3
4
Settings (Step 3 Setting Using the V.Networks Controller)
63
1
Message
Message entered in the textbox will be
displayed when there is an alarm input.
(Up to 100 single-byte characters)
2
Recording
Starts recording when there is an alarm input.
Non-stop :Recording continues until the Stop
button is pressed.
1 minute :Recording stops after 1 minute.
3
Playing wave file
Plays back a designated Wave file when there
is an alarm input. Click the [Browse] button to
specify a file.
4
Execute application file
Executes a designated program when there
is an alarm input. Click the [Browse] button to
specify a program.
Notes
The [1 minute] mode is used for conserving
hard disk space.
In this mode, recording stops after 1 minute
even if recording has already started
before the alarm input.
Note
Alarm actions may be delayed due to PC
performance if a large Wave file (.wav) is
selected.
Notes
Alarm Operation
The following settings are required for the operation of the set alarm.
1. [Alarm Reg] is checked. This item is located under the [Setting] menu of the "V. Networks
Controller". (
Page 57)
2.
All alarm settings in the [Alarm Setting] of the "VN-C205U Setup Tool" are enabled. (
Page 40)
Relay Alarm
When the Relay Alarm function is enabled, subsequent alarms will not be activated.