3. Use the table below only as a starting point for determining Scan Area
values.
NOTE: Keep the Line Offset (y): at the default value of 0 and keep Pixel
Summing at the default value of None.
IMPORTANT: The Pixel Offset must be greater than or equal to the first
calibrated pixel and # Pixels must be less than or equal to the
last calibrated pixel minus the first calibrated pixel.
Cut-Gate Film
Holders
Magnification # Pixels Pixel Offset # Lines
File Size
(MB)
35 mm double-
perforated
0.50 1033 2484 1460 4.3
1.03 2129 1936 3008 18.3
2.00 4133 934 5840 69.1
46 mm 0.50 1754 2123 2554 12.8
0.60 2105 1948 3065 18.5
1.58 5542 229 8071 128.0
6 x 4.5 cm
vertical
0.50 2368 1816 1539 10.4
0.66 3126 1437 2031 18.2
1.26 5967 17 3878 66.2
6 x 4.5 cm
horizontal
0.50 1539 2231 2368 10.4
0.66 2031 1985 3126 18.2
1.26 3878 1061 5967 66.2
6 x 6 cm 0.50 2368 1816 2250 15.2
0.55 2605 1698 2475 18.5
1.26 5967 17 5670 96.8
6 x 7 cm 0.50 2368 1816 2775 18.8
1.26 5967 17 6994 119.4
6 x 9 cm 0.50 2368 1816 3325 22.5
1.19 5636 182 7914 127.6
Split 70 mm 0.50 2483 1759 1632 11.6
0.63 3129 1436 2056 18.4
1.20 5960 20 3917 66.8
70 mm 0.50 2682 1659 3450 26.5
1.09 5846 77 7522 125.8
4 x 5 in. 0.50 3972 1014 5026 57.1
0.74 5878 61 7439 125.1
max mag 2.00 6000 0 7333 125.9
min mag 0.50 2917 1542 3750 31.3