Chapter 4 Digital I/O Functionality
NI 1450 Series Compact Vision System User Manual 4-2 ni.com
TTL Inputs and Outputs
TTL is a fast-switching 5 V digital signaling standard commonly used
for applications that require high precision, such as camera triggering.
TTL inputs and outputs do not require a separate power supply.
Caution Do not connect voltage or current sources to TTL outputs. Doing so could
damage the NI 1450.
Table 4-1 summarizes the TTL inputs and outputs available on the NI 1450.
Isolated Inputs and Outputs
The isolated inputs and outputs on the NI 1450 have a separate ground
reference from the main NI 1450 supply, providing an easy means to
prevent ground loops that can introduce noise into a system. You can apply
signals up to 30 V to the isolated inputs. The voltage swing of the isolated
outputs is determined by the Viso you supply on the connector.
Table 4-2 summarizes the isolated inputs and outputs available on the
NI 1450.
Table 4-1. TTL Inputs and Outputs
Primary
Function
Input or
Output
Number
Available
Signal Names
44-Pin DSUB
on NI 1450
Pin Number
37-Pin
Terminal Block
Pin Number
Trigger Input 2 TTL Input 0
TTL Input 1
1
16
1
2
Timed Pulse Output 6 TRIG 1, Pulse 5
TRIG 2, Pulse 6
TTL Output 1, Pulse 1
TTL Output 2, Pulse 2
TTL Output 3, Pulse 3
TTL Output 4, Pulse 4
—
—
4
6
7
18
—
—
5
7
8
20
Watchdog Output 1 TTL Output 0 3 4
General-Purpose Output 3 TTL Output 5
TTL Output 6
TTL Output 7
19
21
22
21
23
24