National Instruments NI 1450 Series Digital Camera User Manual


 
Appendix A Troubleshooting
NI 1450 Series Compact Vision System User Manual A-2 ni.com
Another device on the network is using the IP address assigned to the
NI 1450. Either remove or reconfigure the other device, or reconfigure
the NI 1450 IP address.
The DIP switch settings on the NI 1450 may be invalid, such as all
switches set to the ON position. Change the DIP switch settings and
reset the NI 1450 by pressing the RESET button on the NI 1450 for at
least two seconds.
Error When Configuring IP Settings for the NI 1450
The NI 1450 cannot be configured if the subnet mask or IP address is
incompatible with the network settings. Verify that the values entered for
all network parameters are valid.
Status of NI 1450 in MAX and Vision Builder AI is No Software
Installed
Install application and driver software on the NI 1450. Refer to Chapter 2,
Setup and Configuration, for installation instructions.
No Camera Found
Verify that the total power requirements of the cameras do not exceed the
power the NI 1450 provides on the 1394 bus. Verify that the cameras
comply with the IIDC Digital 1394-based Camera Specification,
Version 1.30.
Hardware Errors
POWER OK LED is Red
The NI 1450 is in one of the following fault conditions:
Shutdown enabled in software, but ISO Input 11 is not turned on
ISO Input 11 is used to indicate to the NI 1450 that all external
devices are ready for operation. When ISO Input 11 turns off, the
NI1450 shuts down. Either turn on ISO Input 11 with an external
source and reset the NI 1450, or disable Shutdown in the software.
Note For prototyping when external equipment is unavailable, Viso can be wired to ISO
Input 11 to turn it on.