National Instruments NI 1450 Series Digital Camera User Manual


 
Appendix B Specifications
NI 1450 Series Compact Vision System User Manual B-4 ni.com
Environmental
The NI 1450 is intended for indoor use only.
Operating temperature,
vertical mounting position......................0 to 55 °C
Operating temperature,
all other positions....................................0 to 45 °C
Storage temperature................................–55 to 85 °C
Humidity.................................................10 to 90% RH, noncondensing
Pollution Degree.....................................2
Safety
The NI 1450 Series Compact Vision System meets the requirements of the
following standards for safety and electrical equipment for measurement,
control, and laboratory use:
EN 61010-1, IEC 61010-1
UL 3121-1, UL 61010C-1
CAN/CSA C22.2 No. 1010.1
Note For UL and other safety certifications, refer to the product label or visit ni.com.
Electromagnetic Compatibility
Emissions................................................EN 55011 Class A at 10 m
FCC Part 15A above 1 GHz
Immunity ................................................EN 61326:1997 + A2:2001,
Table 1
EMC/EMI ...............................................CE, C-Tick, and FCC Part 15
(Class A) Compliant