Sony BRC-300P Camcorder User Manual


 
14
Location and Function of Parts
5.1.2 BRC-Z700
Rear
1
VISCA RS-422 connector
75 Ω termination switch
This switch is used when an external sync signal
is utilized. Set it to OFF when this camera is in
the middle of a daisy-chain connection of
multiple cameras. Set it to ON when the
camera is at the end of a daisy-chain
connection or when nothing is connected to
the EXT SYNC IN connector on the camera.
DATA MIX switch
Set the switch to ON to overlap the menu with
the video signal output from the installed
interface board. Set it to OFF not to overlap the
menu.
Remote sensor
This is the sensor for the supplied IR Remote
Commander Unit. This remote sensor does not
function when IMGFLIP is set to ON in the
SYSTEM menu.
IR SELECT switch
Selects the camera number when you operate
multiple cameras with the same IR Remote
Commander Unit.
RGB/COMPONENT connector
2
3
4
5
6
7
VISCA RS-232C IN connector
Connects to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the
previous camera in the daisy chain.
RGB/COMPONENT
VISCA RS-422
1 2 3 4 5 6 7 8 9
EXT SYNC IN VIDEO
IR SELECT
75
1 2 3
OFF ON
DATA MIX
OFF ON
IN VISCA RS-232C OUT S VIDEO
DC IN 12V
R
1 2 3 4 5 6
7 8 9 10 11 12 13
Setting of the BOTTOM switches
O
N
1
2
3
4
O
N
1
2
3
4
1
2
3
4
5
Switch 1 (59.94i/50i signal format selector)
Set to ON for output of 50i signal format, or OFF
for output of 59.94i signal format.
Switch 2 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 3 (
Communication baud rate selector
)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switch 4 (Infrared signal output switch)
Set to ON to enable an infrared signal output,
or OFF to disable the output.
Camera address selectors
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
1
2
3
4
5
Please note that the same camera address
cannot be assigned to two or more different
cameras. Furthermore, you must set the switches
before you turn on camera power.
Note
Switch 4 is not used.
Camera
0 1 2 3 4 5 6 7
address
Switch 1
OFF ON OFF ON OFF ON OFF ON
Switch 2
OFF OFF ON ON OFF OFF ON ON
Switch 3
OFF OFF OFF OFF ON ON ON ON
Pin No. Signal Pin No. Signal
1 Pr/R 9 NC
2 Y/G 10 GND
3 Pb/B 11 GND
4 GND 12 NC
5 GND 13 HD-OUT
6 GND 14 Tri-level Sync/Bi-level VD
7 GND 15 NC
8 GND