Sony BRC-300P Camcorder User Manual


 
19
Location and Function of Parts
8
9
10
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the previ-
ous camera in the daisy chain.
VISCA RS-232C OUT connector
When you join multiple cameras, connect it to
the VISCA RS-232C IN connector of the next
camera in the daisy chain.
VISCA RS-422 connector
VISCA FUNCTION switches
Switch 1
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 (
Communication baud rate selector
)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5 (Camera address selectors)
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
11
Please note that the same camera address
cannot be assigned to two or more different
cameras.
Note
Switch 6 (
59.94i/50i signal format selector
)
Set to ON for output of 50i signal format, or OFF
for output of 59.94i signal format.
Please further note that you must set the switches
before you turn on power to the multiplex unit.
Note
Pin No. Signal Pin No. Signal
1 Pr/R 9 NC
2 Y/G 10 GND
3 Pb/B 11 GND
4 GND 12 NC
5 GND 13 HD-OUT
6 GND 14 Tri-level Sync/Bi-level VD
7 GND 15 NC
8 GND
Camera
0 1 2 3 4 5 6 7
address
Switch 3
OFF ON OFF ON OFF ON OFF ON
Switch 4
OFF OFF ON ON OFF OFF ON ON
Switch 5
OFF OFF OFF OFF ON ON ON ON
9
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit.
When you join multiple cameras, connect it to
the VISCA RS-232C OUT connector of the
previous camera in the daisy chain.
8
5.2.2 BRU-300/300P SD Optical
Multiplex Unit for use with the
BRC-300/300P
Rear
1
Card slot
AC IN connector
EXT SYNC IN connector
EXT SYNC OUT connector
Composite video output connector
S-VIDEO connector
VISCA RS-422 connector
VISCA FUNCTION switches
Switch 1
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 (
Communication baud rate selector
)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5 (Camera address selectors)
Set the address of the camera. Normally set to
0. With this setting, addresses are assigned to
the cameras automatically in the connected
order by pressing the POWER button while
holding down the RESET button on the
RM-BR300 Remote Control Unit. You can assign
the camera address, 1 to 7, manually by setting
these selectors as follows:
2
3
4
5
6
7
IN EXT SYNC OUT
S VIDEO
VISCA RS-232C CAMERA
~
AC IN
IN OUT
VISCA RS-422
FUNCTION
1
6
1 2
3 4 5 6 7 8 9 10 11
Please note that the same camera address
cannot be assigned to two or more different
cameras.
Note
Switch 6 is not used.
Camera
0 1 2 3 4 5 6 7
address
Switch 3
OFF ON OFF ON OFF ON OFF ON
Switch 4
OFF OFF ON ON OFF OFF ON ON
Switch 5
OFF OFF OFF OFF ON ON ON ON