13.9 Data Mix
13.8 Function priority
By setting the DATA MIX switch to ON, you can overlap the menu on top of the video signal output from the
installed interface board. When the switch is set to OFF, the menu does not overlap the video. The switch
setting of the BRU-H700 takes priority over that of the BRC cameras. For example, if the switch of the BRU-
H700 is ON and the switch of the camera is OFF, the menu will be displayed on the video images.
This table shows which setting takes priority over the other in each function when the
BRC-H700/BRC-Z700/BRC-300/300P is connected to the BRU-H700/BRU-300/300P.
DATA MIX switch on the BRC-H700 (rear) DATA MIX switch on the BRC-Z330 (rear)
DATA MIX switch on the BRC-Z700 (rear) DATA MIX switch on the BRU-H700 (front)
BRC cameras BRU
RS-232C/RS-422 control disable enable
DATA MIX setting disable enable
VISCA ID setting disable* enable
VIDEO OUT enable enable
* The camera number setting at camera unit should be 0 (Auto).