Sony HDW-F900H Camcorder User Manual


 
4-31
HDW-F900 P1E2
BATT ALARM page
Item Setting Description
BATT TYPE LITHIUM, DIGITAL, Selects the battery to be connected, to the battery terminal. (Same as
OTHERS1
b)
, the BATT ALARM page in the OPERATION menu.)
OTHERS2
b)
, By this setting, the battery alarm voltage indication in accordance with
AC ADP
c)
the features of the battery or the power supply becomes possible.
BEFORE END 11.0 to 17.0 V Sets the alarm voltage indicating that the battery is wearing out. When
the AC ADP is selected, this setting is unavailable, - - - is displayed
showing invalid.
END 11.0 to 17.0 V Sets the alarm voltage indicating that the battery has worn out. When
the AC ADP is selected, this setting is unavailable, - - - is displayed
showing invalid.
DC IN TYPE LITHIUM, DIGITAL, Selects the power running in the DC IN connector. (Same as the BATT
OTHERS1
b)
, ALARM page in the OPERATION menu.)
OTHERS2
b)
, By this setting, the battery alarm voltage indication in accordance with
AC ADP
c)
the features of the battery or the power supply becomes possible.
BEFORE END 11.0 to 17.0 V Sets the alarm voltage indicating that the DC power is wearing out.
When the AC ADP is selected, this setting is unavailable, - - - is
displayed showing invalid.
END 11.0 to 17.0 V Sets the alarm voltage indicating that the DC power has worn out.
When the AC ADP is selected, this setting is unavailable, - - - is
displayed showing invalid.
b) Select OTHERS1 and 2 when using the batteries other than LITHIUM, DIGITAL, AC ADP or the power supply.
c) Select the AC ADP, when using the AC/DC power supply of AC-550/550CE.
OTHERS1 page
Item Setting Description
H PHASE _3072 to 1023 Adjusts the H phase.
MONITOR OUT
Y _30 to 30 Sets the Y output level at MONITOR OUT (BNC).
d)
Pb/Pr _30 to 30 Sets the Pb and Pr output level at MONITOR OUT (BNC).
d)
d) Used to adjust the error resulting from variation of 75 Z termination.
Prior to adjusting the video level at MONITOR OUT, be sure to adjust video levels on the waveform monitor using a camera color-
bar.
4-7. MAINTENANCE Menu
<BATT ALARM>
BATT
TYPE : LITHIUM
BEFORE END : 11.5V
END : 11.0V
DC IN
TYPE : AC ADP
BEFORE END : --
END : --
(Display is initial values.)
<OTHERS 1>
H PHASE : 0
MONITOR OUT
Y: 0
Pb/Pr: 0
(Display is initial values.)